logo
Σφραγίδα

Λεπτομέρειες Blog

Created with Pixso. Σπίτι Created with Pixso. Ιστολόγιο Created with Pixso.

Sandia Advances Highvoltage Metrology With Lithium Niobate BAW Sensors

Sandia Advances Highvoltage Metrology With Lithium Niobate BAW Sensors

2026-10-26

Sandia National Laboratories’ Primary Standards Laboratory is pursuing new sensing technology to address a long-standing accuracy bottleneck in non-DC high-voltage measurement. The work aims to develop an alternative to the resistive divider that currently serves as the reference standard, potentially reducing uncertainty in measurements above 10 kV. Researchers say the effort could also strengthen international standards for high-voltage reference measurement systems.

The precision challenge in high-voltage measurement

High-voltage calibration currently relies heavily on the NIST-N1 resistive divider developed by the National Institute of Standards and Technology. As the principal reference for calibration transfer standards, NIST-N1 has an expanded measurement uncertainty of 0.5% at a 95% confidence level.

For pulse voltage measurement, that figure has become the dominant source of overall uncertainty. Because NIST-N1 is the only currently available device for high-voltage pulse measurement, an alternative system capable of measuring voltage directly is significant for strengthening International Electrotechnical Commission standards in high-voltage reference measurement systems.

Bulk acoustic wave sensing emerges as a candidate

The research team compared several sensing mechanisms, including free-space optical systems using the Kerr or Pockels effect and fiber-optic sensors. Fiber-optic sensors reduce alignment complexity but remain affected by temperature effects and measurement errors caused by path-length differences. Surface acoustic wave sensors offer high sensitivity, but because their substrates are typically less than 1 mm thick, they are difficult to scale for applications above 10 kV.

Bulk acoustic wave sensors use thicker piezoelectric crystals, making them better suited to high-voltage signals. The Sandia work extended BAW sensor applications from a previous 1100 V DC range to DC, AC and pulsed voltage signals. By comparing two lithium niobate crystal orientations, researchers analyzed how acoustic mode propagation affects sensor performance.

Extending from DC to pulsed signals

The expanded testing moves the technology beyond steady direct-current measurement and toward the signal types encountered in high-voltage pulse and alternating-current environments. That shift is central to the laboratory’s effort to develop a practical alternative to existing reference standards.

Modeling and uncertainty analysis

The study used a one-dimensional impedance matrix method to model the crystal, incorporating two acoustic ports and one electrical port. Using piezoelectric constitutive relations, researchers converted voltage-induced strain into an incremental change in crystal length, establishing a direct link between voltage and strain.

The approach provided a theoretical basis for measuring DC voltages from 256 V to 1100 V and supported development of a complete uncertainty budget for the measurement system. The modeling framework is intended to help assess both the performance and the limits of the BAW sensing approach as work advances toward higher-voltage applications.

Parameter Detail
Current high-voltage reference NIST-N1 resistive divider
Measurement uncertainty 0.5% at 95% confidence
Target application range Above 10 kV
BAW prior demonstrated range 1100 V DC
BAW expanded signal types DC, AC and pulsed voltage
Modeled DC range 256 V to 1100 V
SAW substrate thickness Typically less than 1 mm

Frequently Asked Questions

Why is Sandia seeking an alternative to the NIST-N1?
NIST-N1 contributes the largest share of uncertainty in high-voltage pulse measurement, at 0.5% at 95% confidence. A system that measures voltage directly could reduce reliance on that single reference standard and improve overall measurement accuracy.
What advantages do BAW sensors offer over SAW sensors?
BAW sensors use thicker piezoelectric crystals, making them better suited to high-voltage signals. SAW sensors typically have substrates less than 1 mm thick, limiting their ability to scale above 10 kV.
How does the 1-D impedance matrix method model voltage measurement?
It combines two acoustic ports and one electrical port. Using piezoelectric constitutive relations, researchers calculate the strain produced by an applied voltage as an incremental change in crystal length, linking electric field strength to dimensional change for precise DC voltage modeling.